This post covers what happened each day in the exciting life of a chemistry researcher during the week of 5/23-27/16.
The first day
- Made a double batch of gold nano-particles (hereby referred to as AuNP) and put them in a centrifuge to spin at 8000 rpm for 15 minutes
- It looks like it plated the centrifuge conical, maybe will do at 5000 rpm for 20 min next time
- Put DI water in conical to make a total of 20 mL of liquid to re-suspend the particles
- Started APTES on 12 vials (broke one), see the methods tab for details
Day two
- Made another double batch of AuNP
- Spun at 5000 rpm for 10 minutes (that failed)
- Shook t re-suspend then put in at 6500 rpm for 15 minutes, looking good
- Sonicated briefly to dislodge gold on the sides of the vial
- Filled to 20 mL with DI
- Finished APTES procedure on 11 vials and put on rotator to coat overnight. (rotation perpendicular to axis of the vial)
- Half had the AuNP from the 8000 rpm spin, and half had AuNP from the 6500 rpm spin
Day 3
- Vials not looking good, only one looks like it might actually work but it looks like it did nothing. Putting that one in the sonicator for a bit.
- Made up 12 new vials with APTES
- Using the new vials with white caps and polymer sealant instead of the black caps with a foil seal
- Did not use aqua regia since they are brand new
- Made up 4 glass slides with APTES
- Going to use to figure out packing density and enhancement factor
- On the vials from yesterday
- The gold has either precipitated out or attached to the foil lid
- Rinsed with DI and left to dry
- Doc Bantz thinks that decanethiol might be our best bet for surface enhancement of the gold
- Will make 3x batch of AuNP
- Will put in the new vials
- 6 total
- 2 at full strength (4 mL AuNP)
- 2 at half strength (2 mL AuNP)
- 2 at 1/4 strength (1 mL AuNP)
- Will put in rotator overnight (rotation in line with the axis of the vial)
- Have one extra APTES ready vial from yesterday, will suspend in sonicator to try and root out why the vials failed. One of the following caused the problem:
- APTES error
- Centrifugation
- Rotation instead of sonication
Day 4
- The vial from the sonicator plated properly
- NO MORE SPINNING AuNP IN CENTRIFUGE
- Set up a vacuum system to speed production of APTES vials
- can now do 32 at a time instead of only 10
- Initial look at vials in rotator looks good
- Shot Raman of yesterday’s seemingly failed batch (except #2 because it is still not plating or precipitating out)
- Vial 11 was the one that was sonicated
- Vial 2 was abandoned
- Scrapped and aqua regia’d ll the vials
- Calculated out the amounts of material needed to make 10 mM decanethiol in ETOH and then made it
- Took vials out of rotator. All six are looking good.
- Rinsed in DI and put in decanethiol and let sit overnight
Day 5, wrapping up for the weekend
- The vials with decanethiol were washed with DI water and it destroyed the plating. They went from a nice dark purple with a gold shine to clear vials. Raman confirmed that all was lost.
- Might rinse in ETOH rather than DI next time
- Put another 6 vials in rotator with same concentration setup at 10 rpm
- Took vials from 4/7/16 (Chemistry FTX) to test if they are losing their qualities over time with a decanethiol enhancement. Raman proved that they are very stable.
- A and E will be kept as stability testers (A with DI and E in air)
- The remainder will be used to detect m-xylene
- Shot Raman of a clean vial with m-xylene in it to get a baseline
- Calculated the materials needed to make a 1 mM solution of m-xylene in ETOH then made up 50 mL of it
- Did the first test with the xylene on the vial from 4/7 labeled F with 1 mM solution of m-xylene
- Put in 2 mL m-xylene, shook for 30 seconds and let sit for 5 minutes
- Emptied and let dry for 10 minutes
- Didn’t give any significant signal
- Took vial 11 (with benzenethiol) and shot baselines
- Did the same as above with m-xylene
- Looks like the signal isn’t there still