Week 1, Starting SURI

This post covers what happened each day in the exciting life of a chemistry researcher during the week of 5/23-27/16.

The first day

  • Made a double batch of gold nano-particles (hereby referred to as AuNP) and put them in a centrifuge to spin at 8000 rpm for 15 minutes
    • It looks like it plated the centrifuge conical, maybe will do at 5000 rpm for 20 min next time
    • Put DI water in conical to make a total of 20 mL of liquid to re-suspend the particles

20160523_135340

  • Started APTES on 12 vials (broke one), see the methods tab for details

Day two

  • Made another double batch of AuNP
    • Spun at 5000 rpm for 10 minutes (that failed)
    • Shook t re-suspend then put in at 6500 rpm for 15 minutes, looking good
    • Sonicated briefly to dislodge gold on the sides of the vial
    • Filled to 20 mL with DI

20160527_110114

  • Finished APTES procedure on 11 vials and put on rotator to coat overnight.  (rotation perpendicular to axis of the vial)
    • Half had the AuNP from the 8000 rpm spin, and half had AuNP from the 6500 rpm spin

Day 3

  • Vials not looking good, only one looks like it might actually work but it looks like it did nothing.  Putting that one in the sonicator for a bit.

20160527_094134

  • Made up 12 new vials with APTES
    • Using the new vials with white caps and polymer sealant instead of the black caps with a foil seal
    • Did not use aqua regia since they are brand new

20160526_145513

  • Made up 4 glass slides with APTES
    • Going to use to figure out packing density and enhancement factor
  • On the vials from yesterday
    • The gold has either precipitated out or attached to the foil lid
    • Rinsed with DI and left to dry
    • Doc Bantz thinks that decanethiol might be our best bet for surface enhancement of the gold
  • Will make 3x batch of AuNP
    • Will put in the new vials
    • 6 total
      • 2 at full strength (4 mL AuNP)
      • 2 at half strength (2 mL AuNP)
      • 2 at 1/4 strength (1 mL AuNP)
    • Will put in rotator overnight (rotation in line with the axis of the vial)

20160526_145539

  • Have one extra APTES ready vial from yesterday, will suspend in sonicator to try and root out why the vials failed.  One of the following caused the problem:
    • APTES error
    • Centrifugation
    • Rotation instead of sonication

Day 4

  • The vial from the sonicator plated properly
  • NO MORE SPINNING AuNP IN CENTRIFUGE
  • Set up a vacuum system to speed production of APTES vials
    • can now do 32 at a time instead of only 10

20160526_145525

  • Initial look at vials in rotator looks good
  • Shot Raman of yesterday’s seemingly failed batch (except #2 because it is still not plating or precipitating out)
    • Vial 11 was the one that was sonicated
    • Vial 2 was abandoned
    • Scrapped and aqua regia’d ll the vials
  • Calculated out the amounts of material needed to make 10 mM decanethiol in ETOH and then made it
  • Took vials out of rotator.  All six are looking good.
    • Rinsed in DI and put in decanethiol and let sit overnight

20160526_150616

Day 5, wrapping up for the weekend

  • The vials with decanethiol were washed with DI water and it destroyed the plating.  They went from a nice dark purple with a gold shine to clear vials.  Raman confirmed that all was lost.
    • Might rinse in ETOH rather than DI next time
  • Put another 6 vials in rotator with same concentration setup at 10 rpm
  • Took vials from 4/7/16 (Chemistry FTX) to test if they are losing their qualities over time with a decanethiol enhancement.  Raman proved that they are very stable.
    • A and E will be kept as stability testers (A with DI and E in air)
    • The remainder will be used to detect m-xylene

20160527_110127

  • Shot Raman of a clean vial with m-xylene in it to get a baseline
  • Calculated the materials needed to make a 1 mM solution of m-xylene in ETOH then made up 50 mL of it
  • Did the first test with the xylene on the vial from 4/7 labeled F with 1 mM solution of m-xylene
    • Put in 2 mL m-xylene, shook for 30 seconds and let sit for 5 minutes
    • Emptied and let dry for 10 minutes
    • Didn’t give any significant signal
  • Took vial 11 (with benzenethiol) and shot baselines
    • Did the same as above with m-xylene
    • Looks like the signal isn’t there still